Skip to content

Load Testing

Systems

The following systems were used for performance evaluation:

SystemProviderCPUCoresRAMSSD
A5N46on-premRyzen 9900X2496 GiB4 TB

All systems were configured according the Tuning Guide.

Datasets

The following datasets were used:

DatasetHistory# Pat. ¹# Res. ²# Obs. ³Size on SSD
1M10 years1 M1044 M593 M1045 GiB

¹ Number of Patients, ² Total Number of Resources, ³ Number of Observations

Methods

The load testing tool k6 is used to create load from another host in the same network as the test system.

Single Patient Reads

Results

DatasetSystemVUsReq/smedq95q99
1MA5N46114050.500.741.47
1MA5N46239070.450.570.67
1MA5N46472480.530.590.69
1MA5N468133810.550.670.88
1MA5N4616236780.600.821.21
1MA5N4632383140.731.131.90
1MA5N4648456790.891.583.22
1MA5N4664488681.072.204.12

Patient Everything

Results

DatasetSystemVUsReq/smedq95q99
1MA5N46140.5015.728.354.7
1MA5N46273.0716.931.741.7
1MA5N464162.921.942.359.0
1MA5N468234.930.560.190.2
1MA5N4616261.257.698.7125.1
1MA5N4632258.7119.4174.3202.1